P+F Engineering Process Fieldbus Installations
The fieldbus infrastructure constitutes the backbone of your automation system. Design rules apply analogous to any electrical installation. The following engineering criteria are important for reliability and cost-effectiveness:
A segment is a single circuit with power supply, fieldbus junction boxes, and instruments. The segment connects the control system to multiple instruments. The topology design determines the physical location and connection of power supplies, fieldbus junction boxes, and instruments.
The typical topology for a segment is the trunk-and-spur topology with a main line or master cable (trunk). The trunk connects the power supplies and communication interfaces located in the control room with the field. One or more fieldbus junction boxes mounted where they are easily accessible provides connections for field devices. The connection cable with a length of up to 120 m is called a spur, as it is typically much shorter in comparison to the trunk. This topology fits practically all process plants.
With its many similarities to the topologies known from multi-core trunk cables leading to a fieldbus junction box installed in the field, the trunk-and-spur topology is easy to understand, engineer, and maintain.

Trunk-and-spur topology provides simplicity by design. Each device is connected separay.
The fieldbus junction box is also called the device coupler. Where it is required, ignition protection is scalable through a selection of power supplies and device couplers. This enables economic solutions for any hazardous area.
Download and install the free software tool to easily design and layout your fieldbus segments as well as engineer cable lengths based on the devices you use. Device libraries let you choose the instruments of your favorite manufacturer. Make fieldbus installation a simple click process …
Modern-day device couplers provide reliable protection from typical working conditions such as device exchange, contact bounce, water ingress or power surges, etc. These functions are described in detail here …
FieldConnex simplifies engineering and implementation of fieldbus installations for any process plant in any industry with selections and options for protection from ambient conditions, and for the right availability.
See all fieldbus components for use in non-explosion hazardous areas and find the right components for your plant here …
Fieldbus in hazardous areas requires an infrastructure with ignition protection. See below the topology for any hazardous area: Read the details on methods of ignition protection here …

Identical topology with trunk and spurs for any hazardous area. Selecting the components and installation methods provides ignition protection.
版权与免责声明:凡本网注明“来源:中非贸易网”的所有作品,均为浙江兴旺宝明通网络有限公司-中非贸易网合法拥有版权或有权使用的作品,未经本网授权不得转载、摘编或利用其它方式使用上述作品。已经本网授权使用作品的,应在授权范围内使用,并注明“来源:中非贸易网”。违反上述声明者,本网将追究其相关法律责任。 本网转载并注明自其它来源(非中非贸易网)的作品,目的在于传递更多信息,并不代表本网赞同其观点或和对其真实性负责,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品第一来源,并自负版权等法律责任。 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。